The ecom-CL is an easy to use gas analyser designed for basic combustion monitoring in a variety of applications. The CL is fitted with up to 3 gas sensors, measuring O2, CO & NO, plus Stack and Ambient Temperatures, and Stack Pressure & Draft.

The CL also calculates CO2, Efficiency, Losses, Excess Air and Oxygen correction 0-20%. The instrument is housed in a robust composite case suitable for rugged field use. On board data storage for up to 500 separate readings. An IR printer port transmits data to a portable printer for on-the-spot print-outs.

The onboard computer has 5 pre-programmed fuel types and can store up to 16 programmable as well as a 60 second calibration time. The ecom-CL sample conditioning system consists of a high flow pump and radiant gas cooler with moisture trap. An automatic shut-off activates when the gas cooler filter becomes saturated. Another unique feature of the ecom-CL is an Automatic and Manual CO bypass function which protects the CO sensor from over exposure.


  1. Features
  2. Technical Specs
  3. Options
  4. Parts
  5. Downloads
  6. Videos
  7. Get a quote
  Standard Features   Optional Add-ons   ECOM Advantage  
 
Up to 3 Electrochemical Sensors
Sensor Options: 02, CO, NO
4m Standard Sample Line
10in Probe (up to 538C)
CO Purge Pump to Prevent Oversaturation
Ambient Cooler Sample Conditioner
Flue Gas, Ambient, & Sensor Temperature Sensors
Averaging Tests
CO2, Efficiency, Losses, Excess Air, & O2 Correction Calculations
 
Calibration Gas Kit
 
On-board storage for up to 500 readings.
CO bypass to prevent oversaturation.
Rugged, Durable transport case.

 

 

Product Features

Up to 3 gas sensors (Long life).
+ 100 hPa differential pressure measurement.
Integral thermal printer 58 mm.
Soot measurement via soot pump (option).
Backlit display.
Electronic condensate monitoring.
3-chamber tubing, coaxial sampling probe.
T-Room sensor with magnet for easy fixation on metal surfaces
Emission, temperature and draught measurement without plug connection change.
Internal memory for 300 measurements
ecom PC software (free of charge)
Comprehensive accessory program

Measured Values

O2 (0-21%)
CO (0-4000 ppm)
Gas temperature (0-500oC)
Air temperature (0-99oC)
Pressure (+ 100 hPa)
Differential pressure (+ 100 hPa)

Options:

CO extended range (0-1000 ppm)
NO measurement (0-5000 ppm)

Calculated Values:

CO2, CO (undiluted), NOx, losses, efficiency (0-120%), dew point, mg/kWh, mg/m3, adjustable O2 ref.

Display:

LC display, 70 x 40 mm. 8lines
Graphic-capable
Backlit for optimal reading also in the dark

Sampling Probe:

Coaxial probe 220 mm
3-chamber tubing 2.2m
Fixation cone

Measurement Gas Preparation:

Electronic-monitored condensate trap with dust filter
Soot filter for enhanced particle capture

Operation Safety Features

Temperature trend indication for core stream search
CO switch off without measurement interruption by exceeding of pre-set limit value
Automatic fresh air purging by CO exceeding
Automatic fresh air purging after measurement.

Data Processing

Internal memory for 300 measurements
Data exchange with ecom PC software

Connections

Connection for gas leak detector ecom-LSG
Serial interface for data transfer

Power Supply

Battery/Mains power
Including charger

Transport

Aluminium-framed transport case:
Aluminium-framed transport case with length-adjustable shoulder carrying strap.
Under-case for extra storage (option)
Soft case style:
Leather-imitated transport bag with powerful rear magnets for interment positioning on metal surface, with length-adjustable shoulder carrying strap.

Document storage compartment in the back and side storage compartment for charger and small parts.

Dimensions / Weight

Aluminium-framed transport case:
Approx. 360 x 250 x 250 mm (L x H x W)
Approx. 5 kg (complete)
Soft case style:
Approx. 390 x 250 x 200 mm (L x H x W)
Approx. 4.6 kg (complete)
Item No. Description
1070022

ecom-CL, flue gas analyser with O2 and CO (H2-compensated) Long life sensors, fitted in aluminium-framed case Complete with sampling probe 220 mm incl. thermocouple, with fixation cone, 3-chamber tubing (2.2 m), T-Room sensor with cable incl. fixing cone with magnet, automatic CO switch off and fresh air purge, electronic condensate monitoring, consumables kit, operation manual on USB drive, calibration certificate –issued after 100% calibration in calibration chamber. PC software for data management downloadable free of charge

56641 Under-case to hard case style, approx 380 x 135 x 100 mm, weight approx. 0.9 kg
101653 Pressure kit for usability check (acc. to TRGI 2008): 3 pcs connection hoses each 1.2 m long with quick-fitting, 1 piece each conic test stopple 1/2" - 3/4" and 3/4" - 1 1/4", 1 piece crosspiece with safety valve,1 piece compressed air pump for build-up of test pressure in pipe, 1 piece one-pipe counter cap with swivel nut R2" and quick-fittings, 1 piece each high-pressure test stopple 3/8" to 1/2" and 3/8" to 3/4" with quick-fittings, 3 connector parts. 1 piece syringe 100 ml, 1 under case ecom-CL with foam insert for the safe storage of all components
101654 Pressure kit for usability check, preliminary and tightness check (acc. to TRGI 2008): 3 pcs connection hoses each 1.2 m long with quick-fitting, 1 piece each conic test stopple 1/2" - 3/4" and 3/4" - 1 1/4", 1 piece crosspiece with safety valve, 1 piece compressed air pump for build-up of test pressure in pipe, 1 piece one-pipe counter cap with swivel nut R2" and quick-fittings, 1 piece
each high-pressure test stopple 3/8" to 1/2" and 3/8" to 3/4" with quick-fittings, 3 connector parts,1 piece syringe 100 ml, 1 under case ecom-CL with foam insert for the safe storage of all components.1 ecom-UNO, pressure meter, special version ± 1500 hPa with connection cable CL
1070021 ecom-CL, flue gas analyser with O2 and CO (H2-compensated) Long life sensors, fitted in leather-imitation bag Complete with sampling probe 220 mm incl. thermocouple with fixation cone, 3-chamber tubing (2.2 m), T-Room sensor with cable incl. fixing cone with magnet, automatic CO switch off and fresh air purge, electronic condensate monitoring, consumables kit, operation manual on USB drive, calibration certificate –issued after 100% calibration in calibration chamber. PC software for data management downloadable free of charge
100783 NO measurement (0-5000 ppm). At choice with or without NOx calculation.
100233 Tubing for differential pressure measurement (1.5 m)
31000043 Data cable -> PC (RS 232)
51521 Adapter cable USB / RS 232 (requires 3100043)
100222 T-Room stick – H 28 x L 11 mm
10166 T-Room probe – Length 260 mm with 3 m cable
50538 Soot pump kit – consisting of soot pump, soot comparison scale, tube of piston grease, socket wrench and 200 soot papers
100965 Universal CO multi-hole probe – telescopic (80 - 280 mm)
100943 Universal O2 multi-hole probe - telescopic (80 - 280 mm) with three easily exchangeable sealing plugs for openings from Ø 5 - 25 mm
  Part Part Number Description
Water Trap Filer (10pk) Condensation Trap Filter (10/PK) 50803 Particulate filter located on top of water trap assembly.
In-line Smoke Filter Standard (1 EACH) In-line Smoke Filter Standard (Each) 50803 Standard 3/4" in-line filter in clear plastic casing
Thermal On-board Printer Paper (5/PK) Thermal On-board Printer Paper (5/PK) 50513 Printer paper for on-board thermal printer
6V Lead Acid Main Battery 6V Lead Acid Main Battery 50550 6V Lead Acid Main Battery
9vdc Power Pack 9vdc Power Pack 54692 9vdc Power Pack
12V Vehicle Power Source 12V Vehicle Power Source   12V Vehicle Power Source
220mm SCD Probe Pipe 220mm SCD Probe Pipe 20051 220mm SCD Probe Pipe and Thermocouple with Handle
CL Probe Cone CL Probe Cone 52252 CL Probe Cone
9mm Female Gas Adapter 9mm Female Gas Adapter 100581 9mm Female Gas Adapter
8mm Female Draft Adapter 8mm Female Draft Adapter 100582 8mm Female Draft Adapter
ScanTemp Gun ScanTemp Gun   Infrared Temperature Gun w/ Laser Pointer
Calibration Hoser Calibration Hose   Calibration Hose Attachment with Gas Connector
1 Amp Fuse 1 Amp Fuse   1 Amp Fuse Located Under Power Supply
Thermal Printer Assembly Thermal Printer Assembly 50096 Thermal Printer Assembly
Black Silicone Tubing Black Silicone Tubing 50601 Small Black Silicone Tubing for Water Trap and Calibration Hose
Ambient Air Temperature Stick Ambient Air Temperature Stick 100222 Ambient Air Temperature Stick
CL Carry Case CL Carry Case 50101068 CL Carry Case
CL Under Case CL Under Case 56641 CL Under Case
O2 Sensor O2 Sensor 100750 OO/105
O2 Sensor O2 Sensor 54649 5FO
CO Sensor CO Sensor 54648 A5F
NO Sensor NO Sensor 54650 5NF

Brochures


Manual


Software

No Videos Available
Contact:
Company:
Email Address:
Phone Number:
Comments:



Subscribe to our mailing list

* indicates required

Flue Gas AnalysersPressure MeasurementGas DetectionDiagnosis

AS Technical Solutions Limited • Unit 12c Old Bridge Way • Shefford Industrial Estate •
• Shefford • Bedfordshire • SG17 5HQ
• Tel: +44 (0) 1462 414255 • Email: info@ecomproducts.com
• Company Number: 06980122 • VAT Number: 981778952 • Main Business Website: www.astech-ltd.com
Copyright © AS Technical Solutions 2014